Get comparable SD-WAN and SASE proposals from UK providers
Use Netify to request comparable proposals, demos and pre-sales contacts from named SD-WAN and SASE providers. Research is open, and you approve each request before a supplier receives it. SD-WAN provides the connectivity component of SASE.
- 1. Tell us your requirement
Start with six essentials or paste your existing shortlist.
- 2. Approve who we approach
Named suppliers, an anonymous brief and one agreed scope.
- 3. Compare the written responses
Agree a response target before outreach. We report declines and agree the next step.
Netify is paid by suppliers when an introduction leads to business. Commission never affects the evidence order.
Prepare my sourcing plan →Energy & Utilities Buyer's Guide · Last reviewed 19 November 2026
SD-WAN & SASE for Energy and Utilities
Electricity generators, transmission and distribution network operators (TNOs and DNOs), gas transporters, water and wastewater utilities, battery energy storage systems (BESS) and renewable power operators run critical national infrastructure (CNI) where wide-area network availability directly governs physical safety and essential public supply. As legacy time-division multiplexing (TDM), private MPLS circuits and serial telemetry lines reach end of life, energy and utility buyers are adopting Software-Defined Wide Area Networking (SD-WAN) and Secure Access Service Edge (SASE) to unify corporate IT and operational technology (OT) connectivity.
This buyer’s guide explains how to specify, evaluate and procure SD-WAN and SASE for UK and multi-national energy and utility estates. It covers Purdue and IEC 62443 IT/OT segmentation, compliance with the UK Network and Information Systems (NIS) Regulations 2018 and NCSC Cyber Assessment Framework (CAF), EU NIS2 obligations for cross-border operators, remote substation and offshore resilience across 4G, 5G and Low Earth Orbit (LEO) satellite, Zero Trust contractor access and a complete Request for Proposal (RFP) checklist.
Written by Harry Yelland (19 November 2026). Fact-checked by Robert Sturt (19 November 2026).
Supplier Evidence & Shortlist
Looking for evaluated suppliers with energy and utilities sector evidence rather than the OT, NIS and procurement guide? See the evaluated energy and utilities providers.
Your buying project
Start a energy project without re-entering this context
Review the suggested sector requirements in your private project. Use a short brief, a Short or Detailed RFP, or your own RFP or RFI. Your answers carry into the buying workspace; you decide when to publish.
Energy and utilities shortlist tool
Which vendors fit your estate?
Preview aggregate coverage against energy, utility and critical national infrastructure requirements. Private provider matching follows verified project publication.
Energy and utilities priorities
Quick-start presets. Each one sets the matching capability requirements below, where you can refine feature by feature.
Operating model
Operators of Essential Services often run co-managed architectures so internal OT security engineers retain change approval while the provider monitors transport 24x7.
Organisation size
Large network operators require strict multi-domain separation between corporate IT, field depots and operational technology zones.
Regions you must cover
Include every generation asset, onshore or offshore control centre, interconnect and corporate office. Cross-border EU assets bring NIS2 into scope alongside UK NIS.
Cloud platforms
Select the cloud platforms hosting smart-grid analytics, asset management, digital twins and trading or retail billing systems.
AI capability
AIOps assists with anomaly detection on remote cellular and satellite underlays. AI security analytics supports NIS CAF Objective C detection.
Deployment ceiling
New battery storage sites, renewable connections and depot openings need rapid cellular or satellite turn-up ahead of fixed fibre delivery.
Scoring profile
Security led suits IT/OT segmentation and ZTNA contractor access. Network led suits substation MPLS migration and dual-WAN telemetry.
Resilience and size
Control rooms, substations and pumping stations require tested multi-path failover across fibre, 4G/5G and LEO satellite.
Capability requirements (all 40 graded features)
Click once for required, twice for preferred, three times to clear. Energy priorities above pre-select the relevant features.
Or describe your estate to the AI advisor
The advisor maps plain language onto these same filters and explains the result. It can also compare two providers head to head.
Open the full interactive filter at the SASE and SD-WAN shortlist tool or review the energy and utilities provider evaluation page.
What energy and utilities buyers need from SD-WAN and SASE
An energy or utility wide-area network spans environments that share almost nothing with a standard commercial office estate. A single operator routinely connects thermal, nuclear, hydro, wind or solar generation assets, grid-scale battery storage compounds, primary and secondary substations, water treatment works, pumping stations, 24/7 operational control rooms, regional engineering depots, smart-meter and field-force gateways and corporate trading or retail billing offices. Each site category carries distinct physical, environmental, latency and regulatory requirements.
At generation plants, substations, compressor stations and water treatment facilities, operational technology systems monitor and actuate physical processes through Supervisory Control and Data Acquisition (SCADA) hosts, Programmable Logic Controllers (PLCs), Remote Terminal Units (RTUs), Intelligent Electronic Devices (IEDs) and Distributed Control Systems (DCS). These systems were designed for isolated deterministic networks and frequently run legacy industrial protocols such as DNP3, Modbus TCP, IEC 60870-5-104 and IEC 61850. Exposing OT subnets to unsegmented corporate WAN routing or intrusive cloud packet inspection can disrupt real-time telemetry or introduce command latency.
At the same time, decarbonisation and distributed energy resources have multiplied the number of unmanned edge sites that require bidirectional data connectivity. Grid operators and independent power producers need real-time visibility into inverter telemetry, battery state-of-charge, transformer dissolved-gas sensors, physical perimeter CCTV and environmental alarms across hundreds of rural, coastal or offshore locations where fixed carrier fibre is either unavailable or prohibitively expensive to construct.
Meanwhile, the corporate and commercial side of an energy or utility business operates high-volume cloud applications: energy trading and risk management (ETRM) platforms, asset management and digital-twin analytics in AWS or Microsoft Azure, Geographic Information Systems (GIS), customer billing platforms and mobile field-service tablets used by thousands of engineers. A modern energy WAN architecture must allow corporate and field workers to reach cloud applications rapidly through local SASE security inspection while keeping operational control planes strictly isolated from internet-facing attack surfaces.
Finally, utilities face acute third-party access risk. Turbine manufacturers, switchgear OEMs, battery integrators and specialist automation contractors require remote diagnostic and maintenance access into plant and substation zones. Traditional shared VPN accounts and inbound firewall port-forwards have repeatedly served as the entry vector for ransomware and state-sponsored intrusions against critical infrastructure. Replacing network-level contractor VPNs with identity-bound, session-recorded Zero Trust Network Access (ZTNA) is one of the highest-priority security outcomes in energy SASE procurement.
IT/OT segmentation and zero trust
The foundational requirement of any energy or utility SD-WAN and SASE design is deterministic separation between Information Technology (IT) and Operational Technology (OT). Industry best practice combines the Purdue Enterprise Reference Architecture with the ISA/IEC 62443 series of standards on industrial automation and control systems (IACS) security. Under IEC 62443-3-2 and IEC 62443-3-3, an estate is partitioned into discrete security zones grouping assets with identical security requirements, connected solely through tightly governed conduits that inspect, restrict and log every inter-zone data flow.
In a Purdue-aligned utility architecture, Level 0 (field sensors and actuators), Level 1 (PLCs, RTUs and protection relays) and Level 2 (local HMI and site supervisory control) reside within isolated plant or substation LAN zones. Level 3 houses site and regional operations, data historians, asset management and engineering workstations. Between Level 3 OT and Level 4/5 corporate IT sits the Level 3.5 Industrial Demilitarised Zone (IDMZ). No traffic should ever pass directly between corporate IT (or the public internet) and Level 0 to Level 3 OT without terminating and re-originating inside the IDMZ.
SD-WAN and SASE play complementary, strictly bounded roles across this model (see our network segmentation glossary guide and our Manufacturing SD-WAN and SASE Buyer’s Guide for related industrial IT/OT patterns). At the physical site edge, the SD-WAN appliance (or integrated Next-Generation Firewall) enforces strict Virtual Routing and Forwarding (VRF) and zone-based firewall conduits. Corporate office Wi-Fi, depot staff computers, physical security CCTV and OT historian replication traffic are placed into separate VRFs with independent cryptographic overlay tunnels and distinct routing tables. A compromise on a depot laptop in the corporate VRF cannot route packets into the substation OT VRF even though both traverse the same physical fibre or cellular underlay.
Crucially, cloud-delivered SASE and Security Service Edge (SSE) inspection must never be placed in the critical path of closed-loop real-time control or substation-to-control-room SCADA polling. Real-time Level 2 and Level 3 SCADA telemetry between remote substations and central control centres should traverse dedicated, encrypted point-to-point or hub-and-spoke SD-WAN overlay conduits terminating in redundant UK control-centre hubs (or private MPLS underlays where retained for teleprotection), bypassing cloud SWG proxy nodes entirely. Cloud SSE services (SWG, CASB, DLP and ZTNA) are applied to Level 4/5 corporate user traffic, mobile field engineers and controlled Level 3.5 IDMZ jump-host or vendor access workflows.
Regulation and assurance map
Energy and water utilities operate under statutory cyber security regulation with legal enforcement powers, competent-authority audits and significant financial penalties for non-compliance. In the United Kingdom, designated Operators of Essential Services (OES) in the electricity, oil, gas and drinking water sub-sectors are regulated under the Network and Information Systems (NIS) Regulations 2018 (legislation.gov.uk). Competent authorities, including the Office of Gas and Electricity Markets (Ofgem) jointly with the Department for Energy Security and Net Zero (DESNZ) for energy, and the Drinking Water Inspectorate (DWI) / DEFRA for water, assess operators against the NCSC Cyber Assessment Framework (CAF) and sector-specific CAF profiles.
Where a UK utility or energy generator also owns, operates or interconnects generation, transmission, storage or retail assets within European Union member states, those operations fall within the scope of the EU NIS2 Directive (Directive (EU) 2022/2555, transposed into national law across EU member states from October 2024), which classifies energy and drinking/waste water as "Sectors of High Criticality" with mandatory management-body liability, supply-chain security vetting and 24-hour incident notification. The table below maps the regulatory and assurance regimes governing energy and utility network procurement to concrete supplier evidence requests (verify current regulator guidance dates on ofgem.gov.uk, gov.uk and ncsc.gov.uk on your publication date).
| Requirement | Scheme & competent authority | What to ask a supplier |
|---|---|---|
| Statutory resilience, protection, detection and incident response for UK Operators of Essential Services (OES) | UK NIS Regulations 2018 and NCSC Cyber Assessment Framework (CAF v3.2) via Ofgem, DESNZ and DWI (legislation.gov.uk / ofgem.gov.uk) | Provide a clause-by-clause mapping showing how the SD-WAN and SASE platform and managed service support NCSC CAF Objective B (network segmentation, identity and access control, cryptographic protection, resilient networks) and Objective C (continuous security monitoring and SIEM log delivery). |
| Zone and conduit segmentation, foundational requirements (FR 1 to FR 7) and security levels (SL 1 to SL 4) for industrial control environments | ISA/IEC 62443 series (IEC 62443-2-4 for service providers, IEC 62443-3-3 for system requirements) | Demonstrate how the edge appliance enforces IEC 62443 zone and conduit boundaries, deep packet inspection for industrial protocols (Modbus, DNP3, IEC 60870-5-104, IEC 61850) and unidirectional or IDMZ-mediated data flows. |
| Cross-border EU energy and utility operations, supply-chain security and statutory incident reporting | EU NIS2 Directive (Directive (EU) 2022/2555) for operators with EU generation, grid, pipeline or trading entities | Detail supply-chain security governance, vulnerability disclosure procedures, EU/UK sovereign data residency options and contractual SLA commitments supporting 24-hour early-warning and 72-hour NIS2 incident reporting. |
| Baseline and audited technical cyber controls across corporate and managed service boundaries | Cyber Essentials Plus (NCSC / IASME) and ISO/IEC 27001:2022 (including ISO/IEC 27019 energy utility controls where applicable) | Supply current Cyber Essentials Plus and ISO/IEC 27001 certificates confirming that the SD-WAN orchestrator, UK SASE PoPs and 24/7 NOC/SOC facilities are within the audited certification boundary. |
| Smart metering, customer billing and workforce personal data protection | UK GDPR, Data Protection Act 2018, Data (Use and Access) Act 2025 and Smart Energy Code (SEC) where applicable | Provide the UK GDPR Data Processing Addendum, sub-processor schedule and technical proof that customer and employee telemetry inspected by SSE nodes remains resident in the UK. |
| Expanded supply-chain and managed service provider regulation for UK critical infrastructure | UK Cyber Security and Resilience Bill (DSIT legislative programme watch item, gov.uk) | Confirm readiness for enhanced incident reporting duties, competent-authority cost-recovery provisions and designated critical supplier assurance requirements under the forthcoming Cyber Security and Resilience Bill. |
Remote-site connectivity and resilience
Physical geography is one of the sternest tests of an energy or utility WAN. Substations, wind farms, solar parks, hydro schemes, gas pressure-reduction stations, reservoirs and wastewater treatment plants are routinely located in rural uplands, coastal headlands or industrial brownfield sites where carrier fibre diversity is sparse. Even where dual fibre circuits are ordered, last-mile duct sharing along a single rural road or bridge frequently exposes both tails to a single excavator strike, flood or landslide.
To achieve genuine transport independence, energy SD-WAN architectures combine fixed Ethernet or FTTP circuits with multi-carrier 4G LTE, 5G cellular (see our analysis of 5G WAN services for business) and Low Earth Orbit (LEO) satellite underlays (such as enterprise Starlink or Eutelsat OneWeb terminals). By terminating fixed fibre, a dual-SIM cellular modem (using roaming or multi-network eSIMs across EE, Vodafone, O2 and Three) and an LEO satellite terminal into the SD-WAN edge appliance, an unmanned substation or generation site maintains three physically independent communications paths with zero shared last-mile infrastructure.
Telemetry and SCADA protocols require careful traffic engineering across these heterogeneous links (see our guide to how SD-WAN supports industrial IoT). While IEC 61850 GOOSE Trip signals within a substation stay on the local high-speed station bus (and inter-substation teleprotection differential signalling typically uses dedicated dark fibre or private wavelength channels), wide-area SCADA polling (DNP3, IEC 60870-5-104), synchrophasor telemetry, voice dispatch and engineering video require stable latency, low jitter and near-zero packet loss. The SD-WAN overlay must continuously probe all active fibre, 4G/5G and LEO satellite paths, pinning primary SCADA polling to the lowest-jitter terrestrial path, applying Forward Error Correction (FEC) and packet duplication during link brownouts, and executing sub-second failover to cellular or LEO satellite if the terrestrial bearer drops.
Hardware form factor and power engineering are equally critical at unmanned field locations. Standard 1U data-centre rack appliances with AC power bricks and fan intakes fail rapidly in unheated substation marshalling kiosks, roadside cabinets or wind-turbine nacelles. Utility RFPs should specify ruggedised, fanless DIN-rail or wall-mount SD-WAN/security appliances rated for extended operating temperatures (-20°C to +60°C or -40°C to +70°C), compliant with IEC 61850-3 and IEEE 1613 electromagnetic immunity standards for electrical substations, and equipped with dual redundant DC power inputs (typically 24V to 48V DC or 110V DC fed directly from the station battery bank) so the WAN router survives mains power loss alongside the RTU.
Further technical reading: 5G WAN services for business resilience and how SD-WAN supports industrial IoT and telemetry.
Secure remote access for OT vendors and contractors
Third-party operational technology vendors, OEM service engineers and specialist automation contractors are essential to modern energy operations, yet they represent one of the highest-risk access pathways under NCSC CAF Principle B.2. Historically, utilities granted OEMs persistent site-to-site IPSec tunnels or dial-in SSL VPN accounts that placed the contractor’s laptop directly onto a plant or Level 3 OT subnet. Once connected, the external device could scan adjacent IP addresses, transfer uninspected files or bridge malware from the vendor’s own corporate network into the utility’s control environment.
A Zero Trust Network Access (ZTNA) architecture (see our ZTNA glossary guide) eliminates inbound firewall holes and network-level VPN placement altogether. In an IEC 62443-aligned ZTNA deployment, lightweight software connectors or bastion gateways are deployed inside the Level 3.5 Industrial DMZ (or dedicated site conduit). These connectors establish outbound-only TLS tunnels to the SASE cloud broker and expose zero listening ports to the public internet or the corporate WAN.
When an external turbine or switchgear contractor needs to perform maintenance, the workflow enforces strict least-privilege governance. First, the contractor authenticates through strong phishing-resistant multi-factor authentication (MFA) federated with the utility’s Identity Provider, and the ZTNA client or browser-based clientless portal verifies the endpoint’s security posture. Second, access is governed by time-bound, just-in-time (JIT) approval: the session is unlocked only for the approved change-control window and frequently requires explicit electronic sign-off by the duty control-room engineer.
Third, the ZTNA broker connects the contractor solely to the specific protocol and asset authorised for that ticket, such as an RDP, SSH or HTTPS engineering jump-host session inside the Level 3.5 IDMZ, never to the underlying network subnet. Every keystroke, screen frame, command and file transfer (scanned inline for malware and data exfiltration) is recorded in an immutable audit log and streamed to the utility’s SOC SIEM, providing complete forensic traceability for internal security teams and Ofgem or DESNZ NIS auditors.
How energy and utilities buy
Regulated utilities in England, Wales and Northern Ireland, covering electricity, gas, water, heat networks and designated energy extraction or port operations, procure under the utilities regime of the Procurement Act 2023 (implemented in February 2025 alongside the Procurement Regulations 2024, legislation.gov.uk), while Scottish utilities follow the Utilities Contracts (Scotland) Regulations 2016. The Procurement Act 2023 gives utility contracting authorities significant procedural flexibility through the Competitive Flexible Procedure and dynamic market qualification systems, allowing utilities to run multi-stage technical and security assurance dialogues, lab proof-of-concept testing for ruggedised OT hardware and negotiated commercial bids before final award.
Because designated Operators of Essential Services carry direct statutory liability under the UK NIS Regulations 2018 (and EU NIS2 where applicable), supply-chain security assurance is a mandatory gate in utility network procurement. Under NCSC Supply Chain Security Guidance and CAF Principle A.2 (Supply Chain), utilities must vet the security architecture, software bill of materials (SBOM), hardware provenance, vulnerability patch SLA and operational personnel clearance of any SD-WAN vendor, SASE cloud provider and managed service integrator.
Sovereignty and telemetry custody require explicit contractual terms. Energy buyers should verify where the vendor’s SD-WAN orchestrator, ZTNA brokers, cryptographic key management and SIEM log buffers are physically hosted, and ensure that no foreign-jurisdiction parent company or offshore NOC can modify routing policies, push unverified firmware into substation CPE or access network topology diagrams without UK-resident cryptographic approval.
Finally, energy and utility buyers must choose deliberately between co-managed and fully managed operating models. Unlike retail chains that often outsource all branch firewall changes to a third-party MSP, most electricity, gas and water utilities require a co-managed model. In a co-managed deployment, the service provider manages 24/7 underlay circuit monitoring, hardware break-fix replacement, carrier escalation and baseline threat intelligence feeds, while the utility’s own UK-based OT and network security engineers retain exclusive approval and execution control over IEC 62443 zone-and-conduit firewall rules, OT routing tables and ZTNA contractor access policies.
During contract negotiation, utility procurement teams should also establish clear service-credit remedies, field spares pools and exit-management obligations. Because substation and generation-site routers often require specialist DNO or site-safety permits (such as National Grid Safety Rules or water-hygiene entry clearance) before a field engineer can enter an enclosure, standard next-business-day courier swap-outs must be backed by pre-staged warm spares held at regional engineering depots. Zero-touch provisioning profiles stored in the SD-WAN orchestrator allow an authorised utility electrical technician to swap a failed DIN-rail gateway on site and restore encrypted SCADA and ZTNA conduits automatically upon power-up.
Large operators vs smaller utilities and energy retailers
The UK energy and utility market includes both large regulated infrastructure operators and a rapidly growing tier of independent generators, storage developers and energy retailers. Matching the SD-WAN and SASE operating model to your organisation’s engineering capacity, geographic footprint and regulatory classification prevents over-engineering small generation sites or under-protecting critical grid assets.
Transmission operators, DNOs, national gas and regional water & wastewater utilities
Large regulated network operators manage hundreds or thousands of substations, treatment works, pumping stations, depots and control rooms, backed by dedicated internal OT security, SCADA telecommunications and enterprise WAN teams. These buyers require co-managed or self-managed orchestration with granular RBAC separating IT and OT administrators, IEC 61850-3 / IEEE 1613 substation-grade hardware alongside high-throughput data-centre appliances, multi-VRF segmentation, automated API integration with their internal SOC SIEM and service-management tooling, and comprehensive UK NIS CAF and IEC 62443 evidence packs. They also frequently maintain hybrid WAN architectures where private optical or dark-fibre rings carry differential teleprotection while SD-WAN overlays unify secondary SCADA, voice, CCTV and corporate traffic.
Independent renewable generators, BESS operators, district energy and energy retailers
Independent wind, solar and battery storage developers, merchant generators, EV charging networks and retail energy suppliers typically operate 5 to 150 unmanned generation or storage compounds and 1 to 10 corporate or trading offices, with lean internal IT teams. These buyers prioritise rapid turnkey deployment using ruggedised cellular and LEO satellite SD-WAN gateways to get new generation assets online ahead of fixed fibre wayleaves, cloud-delivered ZTNA for OEM maintenance contractors and aggregator dispatch interfaces, and a 24/7 UK Managed Detection and Response (MDR) or managed SASE service wrap that provides NIS-ready security monitoring without building an in-house 24/7 SOC.
Energy SD-WAN / SASE RFP checklist
An energy and utilities SD-WAN and SASE RFP must test industrial hardware resilience, IT/OT protocol isolation and statutory NIS / NCSC CAF assurance alongside standard enterprise WAN metrics. Use the Netify RFP Builder, review our Sample SASE and SD-WAN RFP and select technical items from the SASE RFP Question Bank to structure your procurement.
The table below outlines the six core evaluation categories, the technical requirements to specify, the documentary and proof-of-concept evidence to request from bidders and an indicative evaluation weighting structure.
| Evaluation category | Requirements to include | Evidence to request | Weight |
|---|---|---|---|
| IT/OT Segmentation, Purdue & IEC 62443 Conduits | Multi-VRF and zone-based firewall isolation between corporate IT, Level 3.5 IDMZ and Level 0–3 OT, industrial protocol inspection (DNP3, Modbus, IEC 60870-5-104, IEC 61850) and direct control-room overlay paths bypassing cloud SWG proxies. | Reference Purdue / IEC 62443 architecture diagram, packet-walk demonstration showing how SCADA telemetry bypasses cloud SSE while corporate traffic is inspected, and IEC 62443 certifications. | 25% |
| UK NIS Regulations, NCSC CAF & NIS2 Assurance | Alignment with NCSC CAF v3.2 Objectives B and C (Ofgem/DESNZ/DWI profiles), NIS2 readiness for EU assets, UK data and log residency, Cyber Essentials Plus, ISO/IEC 27001 and supply-chain provenance. | Completed NCSC CAF mapping matrix, named UK PoP and orchestrator hosting locations, ISO 27001 SoA, SBOM/supply-chain security statement and 24/7 incident notification SLA. | 20% |
| Substation & Remote-Site Underlay Resilience & Ruggedised CPE | Sub-second failover across fixed fibre, dual-SIM 4G/5G cellular and LEO satellite, FEC/packet duplication for SCADA telemetry, DIN-rail fanless CPE (-40°C to +70°C), IEC 61850-3 / IEEE 1613 immunity and dual redundant DC power inputs. | Hardware datasheets for ruggedised substation appliances confirming IEC 61850-3 / IEEE 1613 and dual DC power, plus lab test results for fibre-to-5G/LEO failover on active DNP3/IEC-104 streams. | 20% |
| Zero Trust Remote Access (ZTNA) for OT Contractors | Outbound-only ZTNA connectors in Level 3.5 IDMZ, phishing-resistant MFA, device posture checks, time-bound just-in-time access approval by control-room staff and full RDP/SSH/HTTPS session recording. | Live demonstration of a contractor JIT access workflow with control-room approval, session recording playback and immediate session revocation. | 15% |
| Co-Managed Operating Model & SOC / SIEM Integration | Granular RBAC separating utility OT engineers from MSP NOC operators, 24/7 UK NOC/SOC monitoring, real-time syslog/API streaming to utility SIEM and field hardware replacement SLAs. | Co-managed RACI matrix, RBAC permission model documentation, SIEM integration guide and 4-hour / next-business-day ruggedised CPE spares replacement coverage map. | 10% |
| Commercial Model, Lifecycle TCO & Exit Terms | 36-month and 60-month pricing across ruggedised and enterprise CPE, SASE/ZTNA licensing (including external contractor seat model), underlay circuits and rate-card flexibility. | Line-item TCO pricing schedule confirming external OT contractor licensing costs (without requiring full enterprise seats for occasional OEM engineers) and clear contract exit terms. | 10% |
How Netify scores suppliers
Netify evaluates SD-WAN and SASE providers using an independent 40-feature capability matrix combined with verified sector evidence for energy, utilities and critical national infrastructure. Every capability grade is backed by primary technical documentation, regulatory attestations and published deployment records, and suppliers without confirmed energy and utilities sector evidence are excluded from the sector ranking.
During technical evaluation, utilities procurement and OT security teams should require shortlisted suppliers to run a live proof-of-concept demonstrating sub-second failover between terrestrial Ethernet, dual-SIM 4G/5G cellular and Low Earth Orbit satellite links while maintaining deterministic jitter for DNP3 and IEC 60870-5-104 SCADA polling. Bidders should also demonstrate role-based access control separation between IT network administrators and OT control-room engineers inside the management console, along with automated syslog and IPFIX telemetry streaming to your Security Operations Centre SIEM.
This buyer’s guide intentionally excludes ranked vendor lists so your engineering, OT security and procurement teams can agree your technical and regulatory specification first. When you are ready to compare evaluated suppliers and their scores, visit our dedicated energy and utilities provider evaluation page.
Open the energy and utilities provider evaluation list or configure custom technical filters in the interactive shortlist tool.
Frequently asked questions
Does cloud-delivered SASE work for Operational Technology (OT) environments?
SASE must be applied selectively across an IT/OT estate rather than routing every industrial packet through a public cloud Security Service Edge (SSE) proxy. Closed-loop control and real-time SCADA polling (such as DNP3, IEC 60870-5-104 and IEC 61850 telemetry between substations, generation sites and 24/7 control rooms) should traverse dedicated, encrypted SD-WAN overlay conduits (within an isolated OT VRF) that connect directly to redundant control-centre gateways, never hair-pinning through cloud SWG inspection nodes. Cloud SASE capabilities, specifically Zero Trust Network Access (ZTNA), SWG, CASB and DLP, are used to secure corporate IT users, mobile field engineers and time-bound OEM contractor access into the Level 3.5 Industrial DMZ.
How do the UK NIS Regulations and the NCSC Cyber Assessment Framework (CAF) affect WAN design?
Under the UK NIS Regulations 2018, designated Operators of Essential Services (OES) in electricity, oil, gas and drinking water are audited by their competent authorities (Ofgem/DESNZ and the Drinking Water Inspectorate) against the NCSC Cyber Assessment Framework (CAF). For WAN and SASE design, CAF Principle B.4 and B.5 require demonstrable network segmentation preventing lateral movement between corporate IT and essential operational functions, resilient multi-path communications without single points of failure and cryptographic protection in transit. CAF Principle B.2 requires strict identity, MFA and least-privilege access control for remote users and third-party contractors, while Principle C.1 requires continuous security telemetry and log ingestion into your SOC SIEM.
Can SD-WAN replace legacy MPLS or private circuits to substations and water treatment sites?
For SCADA monitoring, historian data replication, engineering access, CCTV, IP telephony and corporate connectivity, SD-WAN running over physically diverse fibre, 4G/5G cellular and LEO satellite underlays routinely replaces legacy MPLS and serial circuits while improving visibility, encryption and path availability. The sole exception is ultra-low-latency sub-10ms differential teleprotection signalling between high-voltage transmission substations, which typically remains on dedicated dark fibre, private optical wavelengths or microwave bearers while SD-WAN handles the parallel SCADA, operational and site management networks.
How do 4G/5G cellular and LEO satellite failover perform for remote generation and utility sites?
Combining a terrestrial circuit (or dual-SIM 4G/5G cellular router on multi-network roaming SIMs) with a Low Earth Orbit (LEO) satellite terminal provides true physical path independence for off-grid wind farms, solar parks, BESS compounds, reservoirs and rural substations where terrestrial ducts share a single road or bridge. Modern LEO satellite constellations deliver 25ms to 50ms round-trip latency and high-throughput IP connectivity. The SD-WAN appliance continuously measures latency, jitter and packet loss across fibre, 5G and LEO paths, using Forward Error Correction (FEC) and sub-second path steering to keep SCADA telemetry and remote engineering sessions active when a terrestrial cable is severed.
How should utilities license and control remote ZTNA access for third-party OEM contractors?
Utilities frequently work with hundreds of external OEM engineers who only need diagnostic access for a few hours per quarter. First, architecturally, contractors should connect via clientless browser ZTNA or a posture-checked ZTNA client to a jump host or protocol proxy inside the Level 3.5 Industrial DMZ, with time-bound just-in-time (JIT) approval from the control room and full session recording. Second, commercially, your RFP should require concurrent-session or external-collaborator ZTNA licensing so you do not have to buy full annual enterprise SASE user bundles for every occasional third-party contractor.
What should an energy and utilities SD-WAN and SASE RFP include?
A complete energy RFP should specify: (1) Purdue and IEC 62443 zone-and-conduit VRF segmentation separating corporate IT, Level 3.5 IDMZ and Level 0–3 OT, (2) direct SD-WAN overlay routing for SCADA telemetry alongside cloud SSE for corporate and contractor access, (3) ruggedised DIN-rail fanless CPE specifications (-40°C to +70°C, IEC 61850-3 / IEEE 1613 immunity, dual redundant DC power inputs) for substations and field cabinets, (4) multi-underlay support across fibre, dual-SIM 4G/5G and LEO satellite, (5) UK NIS CAF, NIS2 and UK data residency attestations, (6) co-managed RBAC and SIEM log streaming and (7) transparent 36-month and 60-month TCO schedules. You can generate a complete requirements specification in the Netify RFP Builder.
How we researched this page
This buyer’s guide was written by Harry Yelland and fact-checked by Robert Sturt (Managing Director, Netify Group Limited), with primary regulatory and technical references reviewed on 19 November 2026. Primary sources include the UK Network and Information Systems (NIS) Regulations 2018 (legislation.gov.uk), the NCSC Cyber Assessment Framework (CAF v3.2) and NCSC Zero Trust Architecture Design Principles (ncsc.gov.uk), Ofgem and DESNZ NIS Competent Authority guidance for electricity and gas Operators of Essential Services (ofgem.gov.uk and gov.uk), Drinking Water Inspectorate (DWI) NIS guidance (dwi.gov.uk), the EU NIS2 Directive (Directive (EU) 2022/2555, eur-lex.europa.eu), the ISA/IEC 62443 series on industrial automation and control systems security, IEC 61850-3 and IEEE 1613 substation hardware standards, and the Procurement Act 2023 utilities provisions (legislation.gov.uk).
In accordance with Netify’s editorial and research methodology, buyer’s guides and ranked supplier evaluations are strictly separated so engineering and procurement teams can establish objective requirements before comparing suppliers. Provider capability scores are calculated from traceable public evidence records and are never influenced by commercial referral arrangements. Read our full scoring and evidence rules on the Netify methodology page.
Review our scoring framework and source-verification rules on the Netify methodology page.
Related regulated sectors: Manufacturing & Industrial OT · Government & Public Sector · Healthcare & NHS · Financial Services · Retail